beautypg.com

Atq set result code presentation mode, Atp select pulse dialling, 18 atq set result code presentation mode – Siemens MC35 User Manual

Page 25: 19 atp select pulse dialling

background image

AT Command Set

MC35_ATC_01_V03.02

Page 25 of 228

13.03.2002

2.18 ATQ Set result code presentation mode

Write command

ATQ[]

Response

Specifies whether or not the TA transmits any result code to the TE. Information
text transmitted in response is not affected by this setting.
If =0:
OK
If =1:
(none)

Parameter

0 DCE transmits result code
1 Result codes are suppressed and not transmitted

Reference

V.25ter

Note

2.19 ATP Select pulse dialling

Execute command

ATP

Response

OK

Reference

V.25ter

Note

No effect for GSM

2.20 ATS0 Set number of rings before automatically answering the call

Read command

ATS0?

Response

OK

Write command

ATS0=

Specifies whether or not the TA will accept an incoming data / fax call without
user intervention. determines the number of rings to wait before the TA will
automatically answer.

Response

OK

Parameter

000

disables automatic answer mode

001-255 enables automatic answering after specified number of rings

Reference

V.25ter

Note

• Auto-answer mode is only applicable to data or fax calls.

• If

is set too high, the calling party may hang up before the call can be

automatically answered.

• The correlation between ATS7 and ATS0 is important.

Example: Call setup may fail if ATS0=20 and ATS7=30.