Siemens MC35 User Manual
Page 214
AT Command Set
MC35_ATC_01_V03.02
Page 214 of 228
13.03.2002
Number
Description
Service or option not available class
49
Quality of service unavailable
50
Requested facility not subscribed
55
Incoming calls barred within the CUG
57
Bearer capability not authorized
58
Bearer capability presently not available
63
Service or option not available, unspecified
Service or option not implemented
65
Bearer service not implemented
68
ACM equal or greater than ACMmax
69
Requested facility not implemented
70
Only restricted digital information bearer capability is available
79
service or option not implemented, unspecified
Invalid message (e.g. parameter out of range) class
81
Invalid transaction identifier value
87
User not member of CUG
88
Incompatible destination
91
Invalid transit network selection
95
Semantically incorrect message
Protocol error (e.g. unknown message) class
96
Invalid mandantory information
97
Message type non-existant or not implemented
98
Message type not comaptible with protocol state
99
Information element non-existent or not implemented
100
Conditional information element error
101
Message not compatible with protocol
102
Recovery on timer expiry
111
Protocol error, unspecified
Interworking class
127
Interworking, unspecified
9.1.12 SIEMENS release cause for L3 Call Control (CC) (AT+CEER)
Number
Description
1
Call dropped
2
Service not available
3
Hold procedure not available
4
Temporary no service, previous procedure not yet finished
5
No speech service available
6
Call reestablishment procedure active
7
Mobile received a release (complete) message during a modify procedure (modify re-
ject)
8
Call clearing, because loss of radio connection, if no reestablishment is allowed (call
not active)
10
Number not included in FDN list
Notifications
300
Called party barred incoming call