beautypg.com

At+csq signal quality, 42 at+csq signal quality – Siemens MC35 User Manual

Page 113

background image

AT Command Set

MC35_ATC_01_V03.02

Page 113 of 228

13.03.2002

4.42 AT+CSQ Signal quality

Test command

AT+CSQ=?

Response

+CSQ:

(list of supported s), (list of supported ) OK

Parameter

See execute command

Execute command

AT+CSQ

Response

TA returns received signal strength indication and channel bit error rate
from the ME.
+CSQ: , OK

Parameter

Receive level:
0

-113 dBm or less

1

-111 dBm

2...30

-109... -53 dBm

31

-51 dBm or greater

99

not known or not detectable

Bit error rate:
0...7

as RXQUAL values in the table in GSM 05.08
section 8.2.4.

99

not known or not detectable.

To check the bit error rate there must be a call in progress to
obtain realistic values. If no call is set up, there is no BER to be
determined. In this case the indicated value may be 0 or 99,
depending on the SIM card.

Reference

GSM 07.07

Note