2.7 ATD>
This command can be used to dial a phone number selected from the active memory. The active
memory is the phonebook selected with AT+CPBS (see Chapter 4.29). To set up a call simply enter
the memory location of the desired entry. The memory location range of each phonebook can be
queried by AT+CPBR (see Chapter 4.28).
Execute command
ATD>
TA attempts to set up an outgoing call to the stored number.
Note:
This command may be aborted generally by receiving a character
during execution. It can´t be aborted in some connection setup states,
such as handshaking.
Response
If error is related to ME functionality:
+CME ERROR:
If no dialtone (parameter setting ATX2 or ATX4):
NO DIALTONE
If busy (parameter setting ATX3 or ATX4):
BUSY
If a connection cannot be set up:
NO CARRIER
If successfully connected and non-voice call:
CONNECT
> TA switches to data state.
Note:
When TA returns to command mode after call release:
OK
If successfully connected and voice call:
OK
Parameter
integer type memory location should be in the range of locations
available in the memory used, i.e. the index number returned by
AT+CPBR.
called party)
i Deactivates CLIR (enables presentation of own phone number
to called party)
<;>
Only required to set up voice calls. TA remains in command mode.
Reference
V.25ter/GSM 07.07
Note
• Parameter
• Command is not supported for data call!
• The *# codes can only be used with voice calls (i.e.if “;” is appended).
• See also +ATX and chapter 9.1.5 for