13.03.2002

8.2 AT^MONI Monitor idle mode and dedicated mode

Test command

AT^MONI=?

Response

^MONI: (list of supported < period >

s) OK

Write command

AT^MONI[=riod>]

This command can be used to retrieve information of the serving/dedicated cell
automatically every n seconds. It is cancelled by any character sent to serial port
except if autobauding is enabled (+IPR=0). Then type character ´a´ to abort.

Note:

The two header lines (see below) are output after every ten data lines.

Response

See execute command

Parameter

1 – 254

Display period in seconds

Execute command

AT^MONI

This command can be used to retrieve the cell parameters of the serving/dedicated
cell on request.

Note:

The length of following output lines exceeds 80 characters. Therefore a terminal
program may draw a carriage return on a screen. However, this is not part of the
response.

Response (Examples)

a) ME is camping on a cell:

Serving Cell

I Dedicated channel

chann rs

dBm

PLMN

LAC cell NCC BCC PWR RXLev

C1 I chann TS timAdv PWR

dBm Q ChMod

1013

21

-71 00101 1001 0103

7

7

33

-105

33 I

No connection

b) ME is camping on a cell but searching for a better cell (cell reselection)

Serving Cell

I Dedicated channel

chann rs

dBm

PLMN

LAC cell NCC BCC PWR RXLev

C1 I chann TS timAdv PWR

dBm Q ChMod

1013

4 –106 00101 1001 0103

7

7

33

-105 -35 I

in Reselecting

c) ME is not camping on a cell, could not (yet) find a valid C0 bearer

Serving Cell

I Dedicated channel

chann rs

dBm

PLMN

LAC cell NCC BCC PWR RXLev

C1 I chann TS timAdv PWR

dBm Q ChMod

ME is connected:

Serving Cell

I Dedicated channel

chann rs

dBm

PLMN

LAC cell NCC BCC PWR RXLev

C1 I chann TS timAdv PWR

dBm Q ChMod

1013

19

-76 00101 1001 0103

7

7

33

-105

33 I 1015

1

0

5

-76 0 S_HR

Parameters

Serving Cell:
chann

traffic channel number

rs

RSSI value 0 – 63 (RSSI = Received signal strength indication)

dBm

receiving level in dBm

PLMN

PLMN ID code

LAC

location area code, see note below.

cell

Cell ID, see note below.

NCC

PLMN colour code

BCC

Base Station colour code

PWR

maximal power level used on RACH channel

RXLev

minimal receiving level (in dBm) to allow registration

C1

coefficient for base station selection