2.21 ATS3 Write command line termination character
Read command
ATS3?
Response
<n> OK
Write command
ATS3=
This parameter setting determines the character recognized by TA to terminate
an incoming command line.
Response
OK
Parameter
<n>
000-013-127
command line termination character
Reference
V.25ter
Note
2.22 ATS4 Set response formatting character
Read command
ATS4?
Response
Write command
ATS4=
This parameter setting determines the character generated by the TA for result
code and information text.
Response
OK
Parameter
000-010-127
response formatting character.
Reference
V.25ter
Note
2.23 ATS5 Write command line editing character
Read command
ATS5?
Response
Write command
ATS5=
This parameter setting determines the character recognized by TA as a request
to delete the immediately preceding character from the command line.
Response
OK
Parameter
000-008-127
command line editing character
Reference
V.25ter
Note