beautypg.com

Siemens MC35 User Manual

Page 184

background image

AT Command Set

MC35_ATC_01_V03.02

Page 184 of 228

13.03.2002

8.15 AT^SMGO Set or query SMS overflow presentation mode or query SMS

overflow

Test command

AT^SMGO=?

Response

^SGMO: (list of supported s) OK

Parameter

See write command

Read command

AT^SMGO?

Response

TA returns overflow presentation mode and SMS overflow status
^SGMO: , OK
If error is related to ME functionality:
+CME ERROR:

Parameter

See write command

Write command

AT^SMGO=

Response

TA sets overflow presentation mode
OK

Parameter

SMS overflow presentation mode
0 disable (default)
1 enable

SMS overflow status

0

space available

1

SMS buffer full (buffer for received short messages is . See
AT+CPMS in Chapter 5.11)

2

Buffer full and new message waiting in SC for delivery to ME

Unsolicited result code

When the status SIM overflow changes, an unsolicited result code is sent to TE
^SMGO:

Parameter

See write command

Reference

Siemens

Note

• Indication during data transfer via break (100ms).

• Incoming Class 1 short messages (ME specific) will be preferably stored to

“ME” and may be transferred to the “SM” storage if “ME” is used up. Incoming
Class 2 messages (SIM specific) will be placed to the “SM” storage only.
If messages with different classes are received, the ^SMGO: 2 indication may
be presented, without prior indication of ^SMGO: 1. The indication ^SMGO: 1
means that both buffers ("ME" and "SM") are full. See also Chapter 5.11.

• For more information regarding SIM and ME specific message classes refer to

and the following specifications: GSM 03.38 and 3GPP TS 23.038.