Siemens MC35 User Manual
Page 148
AT Command Set
MC35_ATC_01_V03.02
Page 148 of 228
13.03.2002
Parameter
numeric PDP Context Identifier; if no cid is specified,
nothing will be changed (no profile definition / undefini-
tion)
1
2
numeric parameter for the precedence class
0 network subscribed value
1 High Priority
Service commitments shall be maintained ahead of
precedence classes 2 and 3
2 Normal priority
Service commitments shall be maintained ahead of
precedence class 3
3 Low priority
Service commitments shall be maintained ahead of
precedence classes 1 and 2
numeric parameter for the delay class
0 network subscribed value
SDU size: 128 octets:
Delay Class Mean Transfer Delay 95 percentile
Delay
1 (Predictive) <0.5 <1.5
2 (Predictive) < 5 < 25
3 (Predictive) < 50 < 250
4 (Best Effort) Unspecified
SDU size: 1024 octets:
Delay Class Mean Transfer Delay 95 percentile
Delay
1 (Predictive) <0.5 <1.5
2 (Predictive) < 5 < 25
3 (Predictive) < 50 < 250
4 (Best Effort) Unspecified
The delay parameter defines the end-to-end transfer delay in-
curred in the transmission of SDUs through the GPRS network(s).
numeric parameter for the reliability class
0 network subscribed value
1 Non real-time traffic , error-sensitive application
that cannot cope with data loss
2 Non real-time traffic, error-sensitive application
that can cope with infrequent data loss
3 Non real-time traffic, error-sensitive application
that can cope with data loss, GMM/SM, and SMS
4 Real-time traffic, error-sensitive application that
can cope with data loss
5 Real-time traffic, error non-sensitive application
that can cope with data loss