4.6 AT+CCFC Call forwarding number and conditions control

Test command

AT+CCFC=?

Response

+CCFC: (list/range of supported s) OK

Parameter

See execute command

Write command

AT+CCFC=,
[,
[,[,
[,

Response

TA controls the call forwarding supplementary service. Registration, erasure,
activation, deactivation and status query are supported.

If

≠ 2 and command successful:

OK

If > = 2,

≠ 2 and command successful:

+CCFC: , [, , ]
[+CCFC: ....] OK

If > = 2, > = 2 and command successful:
+CCFC: , [, , [,

If error is related to ME functionality:
+CME ERROR:

Parameter

0 unconditional
1 mobile busy
2 no reply
3 not reachable
4 all call forwarding (includes reasons 0, 1, 2 and 3)
5 all conditional call forwarding (includes reasons 1, 2 and 3)

0 disable call forwarding

1 enable call forwarding
2 query status of call forwarding
3 register and activate call forwarding
4 erase and deactivate call forwarding

string type phone number of forwarding address in format speci-
fied by .
If you select = 3, the phone will be registered
in the network. This allows you to disable / enable CF to the
same destination without the need to enter the phone number
once again. Depending on the services offered by the provider
the registration may be mandatory before CF can be used. The
number remains registered in the network until you register an-
other number or erase it using = 4.

type of address in integer format; default 145 when dialling string in-
cludes international access code character “+”, otherwise 129