Siemens MC35 User Manual
Page 109
AT Command Set
MC35_ATC_01_V03.02
Page 109 of 228
13.03.2002
4.38 AT+CRLP Select radio link protocol param. for orig. non-transparent
data call
Test command
AT+CRLP=?
Response
TA returns values supported by the TA as a compound value.
+CRLP:
(list of supported
), (list of supported
OK
Parameter
See write command
Read command
AT+CRLP?
Response
TA returns current settings for the supported RLP version 0.
+CRLP:
OK
Parameter
See write command
Write command
AT+CRLP= [
[,
[,
Response
TA sets radio link protocol (RLP) parameters used when non-transparent data
calls are originated.
OK
Parameter
0-61
Interworking window size (IWF to MS)
0-61
Mobile window size (MS to IWF)
48-78-255
Acknowledgement timer (T1 in 10 ms units)
1-6-255
Re-transmission attempts N2
0
RLP version number in integer format; when version
indication is not present it shall equal 0.
Reference
GSM 07.07
Note
• RLP version 0: single-link basic version;
• RLP version 1: single-link extended version (e.g. extended by data com-
pression);
• RLP version 2: multi-link version.
• Compression and multi-link are not supported.