beautypg.com

At+crsm restricted sim access, 39 at+crsm restricted sim access – Siemens MC35 User Manual

Page 110

background image

AT Command Set

MC35_ATC_01_V03.02

Page 110 of 228

13.03.2002

4.39 AT+CRSM Restricted SIM access

Test command

AT+CRSM=?

Response

OK

Write command

AT+CRSM=mand>[,
[,,,
[,]]]

Response

By using this command instead of generic SIM Access TE application has eas-
ier but more limited access to the SIM database. As response to the command,
ME sends the actual SIM information parameters and response data.
+CRSM: , [,] OK
If error is related to ME functionality:
+CME ERROR:

Parameter

176

READ BINARY

178

READ RECORD

192

GET RESPONSE

214

UPDATE BINARY

220 UPDATE

RECORD

242 STATUS

all other values are reserved

integer type; this is the identifier for an elementary
data file on SIM. Mandatory for every command ex-
cept STATUS

,,

integer type; parameters passed on by the ME to the
SIM

information which shall be written to the SIM (hexa-
decimal character format)

,

integer type; information from the SIM about the exe-
cution of the actual command. These parameters are
delivered to the TE in both cases, on successful or
failed execution of the command

response of a successful completion of the command
previously issued (hexadecimal character format)

Reference

GSM 07.07

Note