4.39 AT+CRSM Restricted SIM access
Test command
AT+CRSM=?
Response
OK
Write command
AT+CRSM=
[,
[,]]]
Response
By using this command instead of generic SIM Access TE application has eas-
ier but more limited access to the SIM database. As response to the command,
ME sends the actual SIM information parameters and response data.
+CRSM:
+CME ERROR:
Parameter
176
READ BINARY
178
READ RECORD
192
GET RESPONSE
214
UPDATE BINARY
220 UPDATE
RECORD
242 STATUS
all other values are reserved
integer type; this is the identifier for an elementary
data file on SIM. Mandatory for every command ex-
cept STATUS
integer type; parameters passed on by the ME to the
SIM
information which shall be written to the SIM (hexa-
decimal character format)
integer type; information from the SIM about the exe-
cution of the actual command. These parameters are
delivered to the TE in both cases, on successful or
failed execution of the command
response of a successful completion of the command
previously issued (hexadecimal character format)
Reference
GSM 07.07
Note