beautypg.com

At+gcap request complete ta capabilities list, At+gmi request manufacturer identification, At+gmm request ta model identification – Siemens MC35 User Manual

Page 35: 39 at+gcap request complete ta capabilities list, 40 at+gmi request manufacturer identification, 41 at+gmm request ta model identification

background image

AT Command Set

MC35_ATC_01_V03.02

Page 35 of 228

13.03.2002

2.39 AT+GCAP Request complete TA capabilities list

Test command

AT+GCAP=?

Response

OK

Parameter

Execute command

AT+GCAP

Response

TA reports a list of additional capabilities.
+GCAP:
OK

Parameter

e.g.:

+CGSM,+FCLASS

Reference

V.25ter

Note

+CGSM: The response text shows which GSM commands of the ETSI standard
are supported.

2.40 AT+GMI Request manufacturer identification

Test command

AT+GMI=?

Response

OK

Execute command

AT+GMI

Response

TA reports information to identify the manufacturer.
SIEMENS
OK

Reference

V.25ter

Note

See also ”AT+CGMI Request manufacturer identification”.

2.41 AT+GMM Request TA model identification

Test command

AT+GMM=?

Response

OK

Execute command

AT+GMM

TA reports one or more lines of information text which permit the user to identify
the specific model of device.
MC35
OK

Reference

V.25ter

Note

See also ”AT+CGMM Request model identification”.