Siemens MC35 User Manual
Page 34
AT Command Set
MC35_ATC_01_V03.02
Page 34 of 228
13.03.2002
2.38 AT&W Store current configuration to user defined profile
Execute command
AT&W[
TA stores the current settings to a user defined profile in the non-volatile memory.
Response
OK or if error is related to ME functionality: ERROR / +CME ERROR:
Parameter
0 number of profile
Reference
V.25ter
Note
The user defined profile will be loaded automatically after PowerUp. Use ATZ to
restore user profile and AT&F to restore factory settings. Until the first use of
AT&W, ATZ works as AT&F. See Chapter 2.32 for details on ATZ and Chapter
2.35 for AT&F.
List of settings stored to user defined profile:
• ATE, ATQ, ATV, ATX, AT+CRC, AT+CMGF, AT+CSDH, AT+CNMI, AT+ILRR,
AT+CMEE, AT^SMGO, AT+CSMS, AT^SACM, ^SCKS, AT+CREG, AT+CLIP,
AT+COPS.
AT&C, AT&D, AT&S, ATS0, ATS3, ATS4, ATS5, ATS6, ATS7, ATS8, ATS10,
ATS18, AT+FCLASS, AT+CBST, AT+CRLP, AT+CR.
User defined profiles in multiplex mode:
• On each multiplexer channel you can save an individual profile.
• List of settings stored to profile on multiplexer channel 1:
ATE, ATQ, ATV, ATX, AT+CRC, AT+CMGF, AT+CSDH, AT+CNMI, AT+ILRR,
AT+CMEE, AT^SMGO, AT+CSMS, AT^SACM, ^SCKS, AT+CREG, AT+CLIP,
AT+COPS.
AT&C, AT&D, AT&S, ATS0, ATS3, ATS4, ATS5, ATS6, ATS7, ATS8, ATS10,
ATS18, AT+FCLASS, AT+CBST, AT+CRLP, AT+CR.
• List of settings stored to profile on multiplexer channels 2 and 3:
ATE, ATQ, ATV, ATX, AT+CRC, AT+CMGF, AT+CSDH, AT+CNMI, AT+ILRR,
AT+CMEE, AT^SMGO, AT+CSMS, AT^SACM, ^SCKS, AT+CREG, AT+CLIP,
AT+COPS. (Parameters for data call are not relevant on channels 2 and 3.)