beautypg.com

Enterasys Networks 2200 User Manual

Page 235

background image

RMON Statistics Screen

Device Statistics Menu Screens

10-11

Multicast Pkts
(Read-Only)

See the total number of good frames received that were directed to a
multicast address. The value of this field does not include frames
directed to the broadcast address.

CRC Align Errors
(Read-Only)

See the number of frames with bad Cyclic Redundancy Checks (CRC)
received from the network. The CRC is a 4-byte field in the data frame
that ensures that the data received is the same as the data that was
originally sent.

Undersized Pkts
(Read-Only)

See the number of frames received whose size was less than the
minimum Ethernet frame size of 64 bytes, not including preamble, but
have a valid CRC.

Oversized Pkts
(Read-Only)

See the number of frames received whose size exceeded 1518 data
bytes, not including preamble, but have a valid CRC.

Fragments
(Read-Only)

See the number of received frames that are not the minimum number of
bytes in length or received frames that had a bad or missing Frame
Check Sequence (FCS), were less than 64 bytes in length (excluding
framing bits, but including FCS bytes), and have an invalid CRC.

NOTE: It is normal for the Fragments field to increment.
Fragments are a normal result of collisions in a half-duplex
network.

Jabbers
(Read-Only)

See the total number of frames that were greater than 1518 bytes and
had either a bad FCS or a bad CRC.

Total Packets
(Read-Only)

See the total number of frames (including bad frames, broadcast
frames, and multicast frames) received on this interface.

Total Octets
(Read-Only)

See the total number of octets (bytes) of data, including those in bad
frames, received on this interface.

64 Octets
(Read-Only)

See the total number of frames, including bad frames, received that
were 64 bytes in length (excluding framing bits, but including FCS
bytes).

Table 10-4

RMON Statistics Screen Field Descriptions (Continued)

Use this field…

To…