Field descriptions – Enterasys Networks 2200 User Manual
Page 138
Transmit Queues Configuration Screen
6-20
802.1 Configuration Menu Screens
Field Descriptions
Refer to
for a functional description of each screen field.
Table 6-6
Transmit Queues Configuration Screen Field Descriptions
Use this field …
To…
Current Queueing
Mode
(Toggle)
Toggle between the STRICT 802.1 and WEIGHTED mode. The
default setting is STRICT 802.1. To set the mode, refer to
Weights Q0, Q1,
Q2, Q3
(Selectable)
Allocate the percentage of port transmission capacity according to
transmit queues Q0 through Q3 (with Q0 being the lowest priority
transmit queue).
NOTE: These selectable fields (Q0 through Q3) do not display
when the Current Queueing Mode is set to STRICT 802.1.
The weights selected must equal 100% or the values cannot be
saved. Default weight distribution is 25% per transmission queue.
Selectable percent weight values per priority transmit queue Q0
through Q3 are as follows: 00, 06, 12, 19, 25, 31, 38, 44, 50, 56, 62, 69,
75, 81, 88, 94, 100. To set the weight per priority, refer to
Port
(Selectable)
Step to the port to be configured. As each port is stepped to, the port
type (e.g., Ethernet front panel) displays to the right of the selected port
number. To display the current weight settings for the selected port,
press ENTER.
Number of Queues
(Read-Only)
See the number of queues.
SET ALL PORTS
(Command)
Set all available ports to the current screen settings.
NOTE: These selectable fields (Q0 through Q3) do not display
when the Current Queueing Mode is set to STRICT 802.1.