1 configuring a port, Configuring a port -47 – Enterasys Networks 2200 User Manual
Page 165
Rate Limiting Configuration Screen
802.1 Configuration Menu Screens
6-47
6.10.1 Configuring a Port
The following describes how to configure a port using the Rate Limiting Configuration screen:
1. To enter a Port Type, proceed to
. To enter a port number, proceed as follows:
a. Use the arrow keys to highlight the field (1) below the Port Number field.
b. Type in the port number and press ENTER.
.
2. To enter a Port Type, proceed as follows:
a. Use the arrow keys to highlight the Port field (near the bottom of the screen) and press the
SPACE bar. Port Number changes to Port Type and the field below it changes to [all
10Mbps enet].
b. Use the arrow keys to highlight the [all 10Mbps enet] field below the Port Type field.
c. If the port type [all 10Mbps enet] is not the selection needed, press the SPACE bar to select
either [all 100Mbps enet] or [all 1Gbps enet].
Max Rate: kbps
–
bottom of screen
(Modifiable)
Enter the maximum transmission rate for this entry. The maximum
transmission rate includes all frames associated with the priorities
selected in the Priority List field. The minimum setting is 100
(100 kbps).
For details on configuring a port, refer to
ADD
–
bottom of screen
(Command)
Add the current port, priority, and maximum rate selections to the
screen. For details about how to configure and add an entry, refer to
.
DEL ALL/DEL
MARKED
–
bottom of screen
(Toggle)
Delete all or one or more marked entries. The DEL ALL command is
the default and it is used to simultaneously delete all the lines of
configured information. The DEL MARKED command appears in
place of the DEL ALL command when one or more lines are marked
for deletion. For details on using the two commands, refer to
.
Table 6-11
Rate Limiting Configuration Screen Field Descriptions (Continued)
Use this field…
To…