Yaskawa MotionSuite Series Machine Controller Software Manual User Manual
Page 331

MotionSuite™ Series Machine Controller Software Manual
Chapter 8: Ladder Programming
8-83
8.5 C Register Creation
The creation of the various global parameter data common to all ladders and functions in
installations, products, etc. is presented below.
8.5.1
C Register List Window Configuration
C register tables are managed according to the list window. The method for opening
the list window, and the structure of the menus are discussed in this item.
Opening the C Register List Window
The list window can be opened from the Engineering Manager. The C register list
stored in the PLC in the on-line mode, and in the hard drive in the off-line mode, is
called out.
Opening from the Engineering Manager
a. Select Open (O)
⇒C Register (C)⇒C Register List (M) from the File (F)
menu.
b. The list window opens.
Appearance of C Register List Window
This window displays a list of stored C registers. The list is displayed in C register
number order. From this window, open the C register table window, and define the C
register contents.
1. Table Name
This column shows the C register name.
2. Register
This column shows the first number of the C register.
3. Size
This column shows the size from the first C register number in word units.
4. Comments
This column shows comments in the C register table.