User name, Password, User privilege – Yaskawa MotionSuite Series Machine Controller Software Manual User Manual
Page 116: Default user, Standard registered user

MotionSuite™ Series Machine Controller Software Manual
Chapter 4: File Manager
4-59
b. The user has been registered.
User Name
Input the user name, using 16 characters or less, but do not use a space or comma.
Duplicate user names cannot be input. Also, since User-A, User-B, and User-C are
already registered as users in the MotionWorks™ system, they cannot be used again.
Password
Input a password that corresponds to the user name, using 16 characters or less. As soon as
the user name is different, the password can be duplicated. Moreover, password input can
be omitted.
User Privilege
Input the read privilege of the program already created to the R (read) row, and the write
privilege of the program already created to the W (write) row in a value range of 0~7. The
larger the value, the greater the privilege.
Default User
Input the read privilege of the newly created program to the R (read) row, and the write
privilege of the newly created program to the W (write) row in a value range of 0~7. The
larger the value, the greater the privilege.
Standard Registered User
In the MotionWorks™ system, a standard registered user has been set up for each PLC.
Moreover, standard user privileges and default privileges are also registered. They are
shown as follows.
Table 4.21: Standard Registered User
User Name
Password
User Privilege
Default Privilege
Reference
USER-A
USER-A
R7W7
R0W1
For user manager
USER-B
USER-B
R1W1
R0W1
For user maintenance personnel
USER-C
USER-C
R1W0
R0W1
For user operator