Yaskawa MotionSuite Series Machine Controller Software Manual User Manual
Page 244

MotionSuite™ Series Machine Controller Software Manual
Chapter 7: System Data Definition
7-71
3. Contact
Displays the contact designation. Contact designation is set in the Failures tab.
4. Rank
This column displays the fault rank. Fault ranks are set in the Failures tab.
5. Memory
Input the fault memory output coil number. Input a bit register number for each
output coil number. The inputtable register types are O and M registers.
6. Unconfirmed Output
Input the unconfirmed fault output coil number. Input a bit register number for
each output coil number. The inputtable register types are O and M registers.
7. Confirmed Output
Input the confirmed fault output coil number. Input a bit register number for
each output coil number. The inputtable register types are O and M registers.
8. Confirmed Input
Input the confirmed fault input relay number. Input a bit register number for
each input relay number. The inputtable register types are S, I, O and M regis-
ters.
9. Reset Input
Input the fault reset input relay number. Input a bit register number for the input
relay number. The inputtable register types are the S, I, O, and M registers.
7.8.4
Fault Status
This item deals with the meaning of items in the Status tab.
Status
The Status tab shows the current fault occurrence state, and whether said faults are
confirmed or unconfirmed. The following screen is displayed upon opening the Fault
Monitor window and clicking the Status tab