Data trace window tabs – Yaskawa MotionSuite Series Machine Controller Software Manual User Manual
Page 219

MotionSuite™ Series Machine Controller Software Manual
Chapter 7: System Data Definition
7-46
Data Trace Window Tabs
The data trace window is composed of three tabs: Data Trace Definition, List, and
Trend Graph.
Helpful Hint
The tabs can be moved in the following order by selecting Next Page (N) from View (V)
in the data trace menu: Data Trace Definition
→List→Trend Graph→Data Trace Defini-
tion. To move the pages in reverse order, select Back Page (P) from View (V) in the data
trace menu.
Table 17: Data Trace Window Menu (Continued)
Menu
Function
Item No.
View (F)
Tool Bar (T)
Displays tool bar
3.4.3
Status Bar (B)
Displays status bar
3.4.3
Mode (M)
RE-DSP (R)
Updates display data
7.7.8
AUTO (A)
Automatic update of display data
7.7.8
Sampling (S)
Number of Read Data (R)
Modifies the number of data rows read
7.7.8
Trace Time Axis (T)
Modifies trace time axis
7.7.8
Jump to Appoint Data (O)
Displays trace data from a desired sample number
7.7.8
Data (D)
Decimal (D)
Displays trace data in decimal form
7.7.8
Hexadecimal (H)
Displays trace data in hexadecimal form
7.7.8
m/s (M)
Switches the time axis units
7.7.8
Next Page (N)
Displays next tab page
7.7.1
Back Page (N)
Displays previous tab page
7.7.1
Window (W)
Cascade (C)
Displays the windows in cascade form
3.4.4
Tile
Displays the windows in tile form
3.4.4
Arrange Icons (A)
Displays arranged icons
3.4.4
Help (H)
About App. (A)
Displays version data
3.4.5
Table 18: Data Trace Window Tabs
Tab Name
Function
Item No.
Data Trace Definition
Defines trace data.
7.7.2
List
Displays trace data lists
7.7.8
Trend Graph
Displays trace data graph
7.7.9