beautypg.com

Environmental specifications – Grass Valley K2 AppCenter v.9.0 User Manual

Page 225

background image

Environmental specifications

The K2 Summit 3G system specification is shown in the following table:

Specification

Characteristic

-40° to +60° C

Ambient Temperature
Non-Operating

10° to +40° C

Ambient Temperature
Operating

Operating 20% to 80% from 10° to +40° C

Non-Operating 10% to 85% from -30° to +55° C

Do not operate with visible moisture on the circuit boards

Relative Humidity

To 10,000 feet

IEC 950 compliant to 2000 meters

Operating Altitude

To 40,000 feet

Storage Altitude

30G 11 ms trapezoid

Non-Operating Mechanical
Shock

0.27 GRMS (5-500Hz)

Random Vibration
Operational

2.38 GRMS overall

.019 g2/Hz (5-100Hz)

.009 g2/Hz (200-350Hz)

.0065 g2/Hz (500 Hz)

Random Vibration
Non-Operational

Information Technology

Equipment Type

Class 1

Equipment Class

Category II Local level mains, appliances, portable equipment, etc.

Installation Category

Level 2 operating environment, indoor use only.

Pollution Degree

The first generation K2 Summit/Solo system specification is shown in the following table:

Specification

Characteristic

-40° to +60° C

Ambient Temperature
Non-Operating

10° to +40° C

Ambient Temperature
Operating

Operating 20% to 80% from 10° to +40° C

Non-Operating 10% to 80% from -30° to +60° C

Do not operate with visible moisture on the circuit boards

Relative Humidity

29 October 2012

K2 AppCenter User Manual

225

Specifications

This manual is related to the following products: