Environmental specifications
The K2 Summit 3G system specification is shown in the following table:
Specification
Characteristic
-40° to +60° C
Ambient Temperature
Non-Operating
10° to +40° C
Ambient Temperature
Operating
Operating 20% to 80% from 10° to +40° C
Non-Operating 10% to 85% from -30° to +55° C
Do not operate with visible moisture on the circuit boards
Relative Humidity
To 10,000 feet
IEC 950 compliant to 2000 meters
Operating Altitude
To 40,000 feet
Storage Altitude
30G 11 ms trapezoid
Non-Operating Mechanical
Shock
0.27 GRMS (5-500Hz)
Random Vibration
Operational
2.38 GRMS overall
.019 g2/Hz (5-100Hz)
.009 g2/Hz (200-350Hz)
.0065 g2/Hz (500 Hz)
Random Vibration
Non-Operational
Information Technology
Equipment Type
Class 1
Equipment Class
Category II Local level mains, appliances, portable equipment, etc.
Installation Category
Level 2 operating environment, indoor use only.
Pollution Degree
The first generation K2 Summit/Solo system specification is shown in the following table:
Specification
Characteristic
-40° to +60° C
Ambient Temperature
Non-Operating
10° to +40° C
Ambient Temperature
Operating
Operating 20% to 80% from 10° to +40° C
Non-Operating 10% to 80% from -30° to +60° C
Do not operate with visible moisture on the circuit boards
Relative Humidity
29 October 2012
K2 AppCenter User Manual
225