K2 summit transmission models specifications, Ac power specification – Grass Valley K2 AppCenter v.9.0 User Manual
Page 224
K2 Summit transmission models specifications
Refer to the section about K2 Summit Transmission models for specifications unique to that system.
If a specification is not unique to a K2 Summit Transmission model, then the general K2 Summit/Solo
system specification found in this section applies.
AC power specification
Table 7: K2 Summit 3G AC power specification
Specification
Characteristic
Dual, redundant
Power supply
90 to 260V auto-range, 47-63Hz
Mains Input Voltage
450W typical (standalone)
390W typical (SAN client)
Maximum AC current 8A @ 115VAC, 4A @ 230VAC
Power consumption
The specification is shown in the following table.
Table 8: First-generation K2 Summit AC power specification
Specification
Characteristic
Dual, redundant
Power supply
90 to 260V auto-range, 47-63Hz
Mains Input Voltage
350W typical (standalone)
300W typical (SAN-attached)
Maximum AC current 7A @ 115VAC, 3.5A @ 230VAC
Power consumption
The specification is shown in the following table.
Table 9: First-generation K2 Solo and K2 Solo 3G Media Server AC power specification
Specification
Characteristic
Single
Power supply
100-240V, 50/60 Hz
Mains Input Voltage
180W typical
Maximum AC current 4A @ 115VAC, 2A @ 230VAC
Power consumption
WARNING: Always use a grounded outlet to supply power to the system. Always use a power
cable with a grounded plug, such as the one supplied with the system.