beautypg.com

11 – machine control/location, Selecting devices for control – Teac DM-24 User Manual

Page 80

background image

80

TASCAM DM-24 Reference Manual

11 – Machine Control/Location

The DM-24 is capable of acting as a remote control
unit for a wide variety of external devices.

The exact functionality of the machine control
depends, of course, on the device to be controlled.

The device control is carried out through the DTRS
control port, the MIDI connections (for MMC), or
the serial port (

RS-422

).

Different devices can be selected for simultaneous
control by the DM-24, with different devices being

controlled in different ways. For instance, it is possi-
ble to select one device to have its transport functions
controlled by the DM-24, while the DM-24 controls
the track arming functions of another device.

NOTE

In this section, the term “controller” is used to refer to a
part of the DM-24 software controlling an external
device, rather than a hardware feature of the device or
the DM-24.

Selecting devices for control

The

EXT CTRL – MIDI/MC

key is used to set up the

control of external devices.

1

With the

SHIFT

indicator lit, press the

EXT

CTRL [MIDI/MC]

key.

2

Use the second soft key to bring up the
machine control screen (

MACHINE CTRL

):

3

With the cursor pointing to either the

<-ADD

or

INFO

buttons, use the dial to scroll through

the list of devices on the right of the screen
that may be controlled by the DM-24
(

SUPPORTED DEVICES

).

4

When a device to be controlled by the DM-24
is selected in the list, move the cursor to the

<-ADD

button, and press

ENTER

. The device

will be added to the list.

To obtain more information regarding a particular
item in the list of devices which may be controlled by
the DM-24, highlight the item, move the cursor to the

INFO

button, and press

ENTER

. A popup screen pro-

vides information regarding the list item.

At the bottom of the list is a key to the method used
for controlling each item in the list:

The current list of devices (at the time of writing) is:

Other devices may be added to the list of supported
devices in the future. If the list does not contain the
name of a device that you wish to control, please
contact your TASCAM dealer regarding the avail-
ability of a software upgrade which contains the con-
trol capability for your device.

Up to 16 devices may be added to the Machine Con-
trol List. If more devices are connected and added to
the list than can be shown on screen, arrow marks
appear at the top and bottom of the list.

Display Meaning

I

Internal devices

R

REMOTE (DTRS)

M

MIDI Machine Control

4

P2 (RS-422)

Device

Screen display

Control
type

MIDI Timecode generator

MTC Generate

I

Cascade mastering

CASCADE MSTR

I

DA-88 DTRS recorder

DA-88

R

DA-38 DTRS recorder

DA-38

R

DA-98 DTRS recorder

DA-98

R

DA-78HR DTRS recorder

DA-78HR

R

DA-98HR DTRS recorder

DA-98HR

R

MMC open-loop control

MMC OPEN

M

MMC closed-loop control

MMC CLOSE

M

VTR (playback only)

VTR PLAYonly

4

2-track VTR with record support

VTR 2Trk REC

4

4-track VTR with record support

VTR 4Trk REC

4

MMR-8 or MMP-16 TASCAM
HD recorder

MMR8/MMR16

4

DAT recorder with timecode
track

TC DAT

4