3 – system-wide options, Option screen, Setup – Teac DM-24 User Manual
Page 20: Upper bar display, Locate display mode, Encoder operation mode, Library direct key operation, Ol/status led type
20
TASCAM DM-24 Reference Manual
3 – System-wide options
The DM-24 provides a number of options which con-
trol the overall functionality of the console.
These are accessed through the
OPTION
and
DIGITAL
screens.
Within these screens, you can (in the
OPTION
screen):
• Set up various interface preferences
• Set up the way in which soloing works
• Set up timecode preferences for synchronization
with other units
and in the
DIGITAL
screen
• Set up the word sync clock
• Choose the digital input and output formats
• Define and make settings for the optional slot cards
These options are described in detail below:
OPTION screen
To access the
OPTION
screen:
1
Press the
SHIFT
key so that the indicator is
lit.
2
Press the
AUX 1-2/OPTION
key.
The screen changes to show the
OPTION
screen. There are four screens available using
the soft keys immediately below the display:
SETUP
,
PREFERENCES
,
SOLO
and
SYNC/TC
.
SETUP
The following options are available from this screen:
Use the § and ¶ cursor keys (or dial) to move the
cursor to the appropriate fields, and then press the
ENTER
key to change the value.
UPPER BAR DISPLAY
This parameter has two
options:
TIMECODE
and
SYSTEM
. When set to
TIMECODE
, the top right field of the display shows
incoming timecode, and when set to
SYSTEM
, certain
system parameters (clock source, solo mode, etc.) are
displayed.
LOCATE DISPLAY MODE
This parameter deter-
mines how a location entry will be shown on the dis-
play: in the timecode position (
TIMECODE DISPLAY
) or
as a separate popup display in the center of the screen
(
LCD Screen Popup
).
ENCODER OPERATION MODE
When using
the encoders (“Rotary encoders (ring LEDs)” on
page 15), or the PODs, the parameter being edited
may sometimes have too many values to allow easy
setting using the encoder (for example, there are 127
different pan positions). Using the
1Step
setting, one
“click” of the encoders corresponds to one step in the
parameter values. Using the
Coarse
option allows the
changing of the parameter values to be accelerated,
with fewer clicks of the encoder.
Holding down the
2ND F.
key while turning the POD
or encoder reverses the usual acceleration mode (if
1Step
is chosen,
2ND F.
+ POD/encoder = acceler-
ated, and if
Coarse
is chosen,
2ND F
. + POD/encoder
= accelerated.
LIBRARY DIRECT KEY OPERATION
This
parameter controls the type of library accessed by the
RECALL
and
STORE
, and the
+
and
–
keys in the
LIBRARY
section to the left of the screen. There are
six choices:
Snapshot
refers to the overall mixer set-
tings,
Gate/Expand
to the dynamics processor settings
for gate and expander effects,
Comp
to the dynamics
processor settings for compression effects,
EQ
to the
equalization setting library, and
Effect1
and
Effect2
to
the first and second internal effector settings, respec-
tively.
If the
+/- Key Direct box
is checked, this allows instant
recall of a library entry selected using the
+
and
–
keys.
OL/STATUS LED TYPE
The
OL/STATUS
LED
indicators above each fader can serve one of two pur-
poses: firstly, if either of the two “overload” options