beautypg.com

17 – specifications—messages and troubleshooting – Teac DM-24 User Manual

Page 129

background image

17 – Specifications—Messages and troubleshooting

TASCAM DM-24 Reference Manual

129

Can’t do MIDI Bulk Load
with timecode running

Shown if an attempt is made to load Bulk Data with timecode running (“Bulk
transfer of data to the DM-24” on page 96)

Can’t assign fader grouping layer.

Shown when an invalid fader grouping is attempted (“Grouping layers” on
page 71)
.

Can’t assign mute grouping layer.

Shown when an invalid mute grouping is attempted (“Grouping layers” on
page 71)
.

Can’t Dump MIDI Sys Ex data.
SysEx filter is set in MIDI/MC
[SETUP] screen]
Press ENTER to continue.

Shown if a MIDI filter has been set up preventing MIDI System Exclusive trans-
mission (“MIDI filtering” on page 84) and an attempt is made to dump data.

Can’t Recall COMP Libraryxxx.

The compressor library entry xxx cannot be recalled as it does not exist (no
data has been written to that library entry) — “Library functions” on page 99

Can’t Recall Effect U1-xxx.

The user effect 1 library entry xxx cannot be recalled as it does not exist (no
data has been written to that library entry) — “Library functions” on page 99

Can’t Recall EQ Libraryxxx

The EQ library entry xxx cannot be recalled as it does not exist (no data has
been written to that library entry)—“Library functions” on page 99

Can’t recall GATE/EXP Libraryxxx.

The gate/expander library entry xxx cannot be recalled as it does not exist (no
data has been written to that library entry (“Library functions” on page 99)

Can’t recall Snapshotxxx.

The snapshot xxx cannot be recalled as it does not exist (no data has been writ-
ten to that library entry)

Can’t recall to Chxx.
GATE/EXP is not inserted.

An attempt has been made to load gate/expander settings from the library to a
module where a gate or expander has not been inserted (“Library functions” on
page 99)
.

Can’t select dual-line
Different Fs mode
Press ENTER key to continue.

An attempt has been made to select dual-line transmission in normal sampling
frequency mode (must be “normal”)— “High sampling frequency” on page 112.

Can’t select dual-line
Different Fs mode
Press ENTER to continue.

An attempt is made to select the dual-line format in normal sampling frequency
mode (“High sampling frequency” on page 112).

Can’t STORE Automation Bank01.

Shown if there is a problem overwriting a protected memory bank (automation)

Cascade connection broken!
Press ENTER to continue.

Shown on cascade master when an existing cascade connection has become
disconnected or is otherwise inoperative (“Cascade card” on page 119).

Ch parameters Setup?
Press ENTER to confirm,
or a cursor key to cancel.

Shown when a global screen has been used to make changes to a range of
channels at one time (for instance aux sends, digital delay, etc.), (“Module oper-
ations” on page 49
.)

CH x is already inserted.

An attempt has been made to assign a second insert loop to a channel which
has already had an insert loop assigned to it (“Assignable returns” on page 36).

Clear all fader grouping layers ?
Press ENTER to confirm,
or a cursor key to cancel.

Shown when the on-screen CLEAR button has been pressed to clear all fader
groups (“Grouping layers” on page 71).

Clear all muting grouping layers ?
Press ENTER to confirm,
or a cursor key to cancel.

Shown when the on-screen CLEAR button has been pressed to clear all mute
groups (“Grouping” on page 69).

Clear Current Automation Event Data?
Press ENTER to confirm,
or a cursor key to cancel.

Shown in automation, when the current data is to be cleared (using soft key 2)

Action

Message

Explanation