Utility:demodulator:rx-rs n/k deep, Utility:demodulator:rx mode, Utility:demodulator:lnb alarm - low – Comtech EF Data SNM-1010L User Manual
Page 96: Utility:demodulator:lnb alarm - high, Utility:demodulator:rx symbol rate

SNM-1010L Data/Control Modem
Revision 0
Front Panel Operation
MN/SNM1010L.OM
3.4.5.5.8
UTILITY:DEMODULATOR:RX-RS N/K DEEP
RX-RS N/K DEEP
225/205 8
Selection of 4, 8, or 16 deep. Press[
←], [→], [↑], or [↓] to move the flashing cursor. Press
[ENTER] to execute the change .
3.4.5.5.9 UTILITY:DEMODULATOR:RX
MODE
RX MODE
CONTINUOUS
Selection of BURST or CONTINUOUS.
Press[
←], [→], [↑], or [↓] to move the flashing cursor. Press [ENTER] to execute the
change.
3.4.5.5.10 UTILITY:DEMODULATOR:LNB ALARM - LOW
LNB ALARM - LOW
0 mA
Alarm is operational below 0.0 mA. Press[
←], [→], [↑], or [↓] to move the flashing cursor.
Press [ENTER] to execute the change.
3.4.5.5.11 UTILITY:DEMODULATOR:LNB ALARM - HIGH
LNB ALARM - HIGH
500 mA
Alarm is operational above 500 mA. Press[
←], [→], [↑], or [↓] to move the flashing
cursor. Press [ENTER] to execute the change.
3.4.5.5.12 UTILITY:DEMODULATOR:RX SYMBOL RATE
3–48