Transmission interface, Indoor unit to outdoor unit message structure, Command message structure (idu to odu) – Comtech EF Data SNM-1010L User Manual
Page 262: B.9 transmission interface
SNM-1010L Data/Control Modem
Revision 0
Specifications
MN/SNM1010L.OM
B.9 Transmission
Interface
Each transmitted data packet consists of 7 bytes of information. The BUC only accepts a
command if the first data byte contains the appropriate address. Commands are only
executed if the checksum coincides, but a status response is sent if the address is correct
and the command number is within the valid range.
B.10
Indoor Unit to Outdoor Unit Message Structure
B.10.1
Command Message Structure (IDU to ODU)
Byte
Name
Description
Value
1
Address
Address of BUC
0x01 to 0x0f
2 Command
Request
Status
TX On/Off
Change Address
Set Carrier Frequency
0x01
0x02
0x03
0x04
3
Data Byte 1
Not used if command:
=
0x01
TX control if command:
=
0x02
New address if command:
=
0x03
Carrier Frequency if command: =
0x04
0xAA
0=Off, 1=On
0x01 to 0x0f
MSbyte
4
Data Byte 2
Not used if command:
=
0x01
Not used if command:
=
0x02
Not used if command:
=
0x03
Carrier Frequency if command: =
0x04
0XAA
0xAA
0xAA
LSbyte
5
Data Byte 3
Not Used
0xAA
6
Data Byte 4
Not Used
0xAA
7
Checksum
Algebraic sum of bytes 1 - 6
B–20