Function select:monitor:receive signal, Function select:monitor:sweep frequency, Function select:monitor:buffer fill – Comtech EF Data SNM-1010L User Manual
Page 74: Function select:monitor:lnb current
SNM-1010L Data/Control Modem
Revision 0
Front Panel Operation
MN/SNM1010L.OM
3.4.2.4 FUNCTION SELECT:MONITOR:RECEIVE SIGNAL
RECEIVE SIGNAL
-45.0 DBM
Displays the current receive signal level.
Range: -140 dBm +10log(SR) to
-85 dBm + 10log(SR)
3.4.2.5 FUNCTION SELECT:MONITOR:SWEEP FREQUENCY
SWEEP FREQUENCY
+ 0 HZ
Displays the current offset frequency or “No Data” (if carrier is not locked).
Range: -500,000 to +500,000 Hz.
3.4.2.6 FUNCTION SELECT:MONITOR:BUFFER FILL
BUFFER FILL
50%
Displays the current plesiochronous buffer fill status percent.
Range: 1 to 99%.
3.4.2.7 FUNCTION SELECT:MONITOR:LNB CURRENT
LNB CURRENT
LNB POWER OFF
Displays the current LNB Current, either 0 to 500 mA in 1 mA steps, or LNB POWER
OFF.
Upon entry, the status is displayed. Press [
↑] or [↓] to make the selection. Press [ENTER]
to execute the change.
3–26