SNM-1010L Data/Control Modem

Revision 0

Remote Control Channel Commands/Responses

MN/SNM1010L.OM

RCCL_n’cr’
RCSB_n’cr’
ROCP_xxxx’cr’
RCT_xxxxx’cr
LPC_xxx’cr’
NOMP_snn.n’cr’
MINP_snn.n’cr’
MAXP_snn.n’cr’
LCL_xxxx’cr’
RCL_xxxx’cr’
ENSP_nn.n’cr’
MAXT_n.n’cr’
RTSM_xxx’cr’
CTSD_xx’cr’’lf’]






ASYNC RX Channel Char Length
ASYNC RX Stop Bits
ASYNC RX Overhead Channel Parity
ASYNC RX Communications Type
AUPC Local Power Enable
AUPC Nominal Power Value
AUPC Minimum Power Value
AUPC Maximum Power Value
AUPC Local Carrier Loss
AUPC Remote Carrier Loss
AUPC EBNO Target Set Point
AUPC Max. Tracking Rate
RTS TX Control Mode
CTS Delay Time

This command is used by the Comtech EF Data M:N
protection switch to collect information necessary for
configuring backup modems.

Notes:

1. Status only returned in Transmit
Continuous

mode.

2. Status only returned in Transmit
Burst

mode.

Current Receive Reed-
Solomon N/K and
interleave Value

Status:
Response:

MC RXRS_’cr’
RXRS_nnn/kkk_ii’cr’’lf’]

Where: nn = N value, kkk = K value and ii = Interleave
value

Descrambler Type

Status:
Response:

MC DSCR_’cr’
DSCR_xxxxxxxxxxxx’cr’’lf’]

Where: xxxxxxxxxxxx = IBS SYNC, EFD MOD V.35,
INTELSAT V.35, FDC MOD V.35, ITU V.35 or OFF.

A–18