beautypg.com

Bulk consolidated analog status, A.8.1 bulk consolidated analog status – Comtech EF Data SNM-1010L User Manual

Page 224

background image

SNM-1010L Data/Control Modem

Revision 0

Remote Control Channel Commands/Responses

MN/SNM1010L.OM

A.8.1

Bulk Consolidated Analog Status

Bulk Consol. Analog
Status

Status:
Response:

MC BCAS_'cr'
BCAS_p1,p2,p3, . . . pn'cr''lf']

This command is similar to the 'BCS_' command,
but returns modem analog parameters. Additional
status of new options and features will always be
appended to the end.

Where 'pn' is the last parameter returned.

Parameter
Number

Parameter Name
(Command Reference)


Description

1


2


3


4


5


6


7


8

Receive Signal Level
(ref. 'RSL_' command).

Raw BER
(ref. 'RBER_' command).

Corrected BER
(ref. 'CBER_' command).

Interface Read Error Status
(ref. 'IRES_' command).

EB/N0
(ref. 'EBN0_' command).

Buffer Fill Status
(ref. 'IBFS_' command).

LNB Current
(ref. LNBC_’ command).

ODU Current
(ref. ODUC_’ command).

p1 = xsnn.n, receive signal level in dBm.


p2 = xm.mE-ee.


p3 = xm.mE-ee.


p4 = tttt_xm.mE-ee.


p5 = xnn.n, EB/N0 in dB.


p6 = nn%, buffer fill status.


P7 = nnn, LNB Current


P8 = nnnn, ODU Current

Note: Parameters 2 through 6 are dependent on carrier acquisition, if the decoder is not locked empty data blocks are returned (,,,,,).



A–26