Modem faults status, A.5 modem faults status – Comtech EF Data SNM-1010L User Manual
Page 217

SNM-1010L Data/Control Modem
Revision 0
Remote Control Channel Commands/Responses
MN/SNM1010L.OM
A.5
Modem Faults Status
Modem Faults Status
(Summary)
Status:
Response:
MC MFS_'cr'
MFS_'cr'
DMD_xxx'cr'
MOD_xxx'cr'
ITX_xxx'cr'
IRX_xxx'cr'
CEQ_xxx'cr''lf']
RX Continuous Mode :
Demodulator (FLT/OK)
Modulator (FLT/OK)
Interface Transmit Side (FLT/OK)
Interface Receive Side (FLT/OK)
Common Equipment (FLT/OK)
Modulator Status
Status:
Response:
Response:
MC MS_'cr'
MS_'cr'
RF_xxx'cr'
MOD_xxx'cr'
SYN_xxx'cr'
DCS_xxx'cr'
AGC_xxx'cr'
SFLT_xx'cr''lf']
MS_'cr'
RF_xxx'cr'
MOD_xxx'cr'
SYN_xxx'cr'
DCS_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
AGC_xxx'cr'
SFLT_xx'cr''lf']
TX Burst Mode :
RF Output (ON/OFF) Actual Status, Not Configured
Module (OK/FLT)
IF Synthesizer (OK/FLT)
Data Clock Synthesizer (OK/FLT)
AGC Level (OK/FLT)
No. of Stored Faults
Logged (0 through 10)
TX Continuous Mode :
RF Output (ON/OFF)
Module (OK/FLT)
IF Synthesizer (OK/FLT)
Data Clock Synthesizer (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
AGC Level (OK/FLT)
No. of Stored Faults Logged (0 through 10)
Demodulator Status
Status:
Response:
MC DS_'cr'
DS_'cr'
MOD_xxx'cr'
CD_xxx'cr'
SYN_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
DSCR_xxx'cr'
BERT_xxx'cr'
SFLT_xx'cr''lf']
RX Continuous Mode:
Demod Module (OK/FLT)
Carrier Detect (OK/FLT)
IF Synthesizer Lock (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
Descrambler (OK/FLT)
BER Threshold (OK/FLT)
Number of Stored Faults Logged (0 through 10)
Interface Transmit
Side Status
Status:
Response:
Response:
MC ITXS_'cr'
ITXS_'cr'
CLK_xxx'cr'
SFLT_xx'cr''lf']
ITXS_'cr'
CLK_xxx'cr'
SFLT_xx'cr''lf']
TX Burst Mode :
Selected Transmit Clock Activity (OK/FLT)
Number of Stored Faults Logged (0 through 10)
TX Continuous Mode :
Selected Transmit Clock Activity (OK/FLT)
Number of Stored Faults Logged (0 through 10)
Interface Receive Side
Status
Status:
Response:
MC IRXS_'cr'
IRXS_'cr'
CLK_xxx'cr'
UNFL_xxx'cr'
OVFL_xxx'cr'
SFLT_xx'cr''lf']
Selected Buffer Clock Activity (OK/FLT)
Buffer Underflow (OK/FLT)
Buffer Overflow (OK/FLT)
Number of Stored Faults
Logged (0 through 10)
A–19