beautypg.com

Fault connector and pinouts (j7), 1 fault connector and pinouts (j7) – Comtech EF Data SNM-1010L User Manual

Page 39

background image

SNM-1010L Data/Control Modem

Revision 0

Installation

MN/SNM1010L.OM

2.3.1

Fault Connector and Pinouts (J7)

The fault connector provides Form C contact closures for fault reporting. The three Form C
summary fault contacts, ratings 1A maximum at 24 VDC, 0.5A at 120 VAC, are
Modulator, Demodulator, and Common Equipment.

The fault interface connection is a 9-pin subminiature female D connector (J7) located on
the rear panel of the modem. Screw locks are provided for mechanical security on the
mating connector. Refer to Table 2-2 for pinout information.

Table 2-2. Fault Connector and Pinouts (J7)

Pin #

Signal Function

Name

1

Common equipment is not faulted

NO

2

COM

3

Common equipment is faulted

NC

4

Modulator is not faulted

NO

5

COM

6

Modulator is faulted

NC

7

Demodulator is not faulted

NO

8

COM

9

Demodulator is faulted

NC

Note: A connection between the common (COM) and normally open (NO) contacts
indicates no fault.

2–5

This manual is related to the following products: