Comtech EF Data SNM-1010L User Manual
Page 206
SNM-1010L Data/Control Modem
Revision 0
Remote Control Channel Commands/Responses
MN/SNM1010L.OM
Receive BPSK Data
Ordering
Command:
Response:
Status:
Response:
MC RDA_xxx'cr'
RDA_xxx'cr''lf']
MC RDA_'cr'
RDA_xxx'cr''lf']
Where: xxx = NRM (Standard) or INV (Non-Standard).
Reed-Solomon Interleave
Value
Command:
Response:
Status:
Response:
MC RRSI_xx'cr'
RRSI_xx'cr''lf']
MC RRSI_'cr'
RRSI_xx'cr''lf']
Where: xx = 4, 8, or 16.
RX 8PSK 2/3 IESS-310
Operation
Command:
Response:
Status:
Response:
MC R310_xxx'cr'
R310_xxx'cr''lf']
MC R310_'cr'
R310_xxx'cr''lf']
Where: xxx = ON or OFF.
LNB Power
Command:
Response:
Status:
Response:
MC LNB_xxx'cr'
LNB_xxx'cr''lf']
MC LNB_'cr'
LNB_xxx'cr''lf']
Where: xxx = ON or OFF.
LNB Voltage
Command:
Response:
Status:
Response:
MC LNBV_xxx'cr'
LNBV_xxx'cr''lf']
MC LNBV_'cr'
LNBV_xxx'cr''lf']
Where: xxx = 13, 18, or 24 volts.
LNB Reference Enable
Command:
Response:
Status:
Response:
MC LNBR_xxx'cr'
LNBR_xxx'cr''lf']
MC LNBR_'cr'
LNBR_xxx'cr''lf']
Where: xxx = ON or OFF.
LNB Power Monitor
Low Current Threshold
Command:
Response:
Status:
Response:
MC LNBL_xxx'cr'
LNBL_xxx'cr''lf']
MC LNBL_'cr'
LNBL_xxx'cr''lf']
Where: xxx = 0 to 500 mA in 1 mA steps
LNB Power Monitor
High Current Threshold
Command:
Response:
Status:
Response:
MC LNBH_xxx'cr'
LNBH_xxx'cr''lf']
MC LNBH_'cr'
LNBH_xxx'cr''lf']
Where: xxx = 0 to 500 mA in 1 mA steps
A–8