beautypg.com

Comtech EF Data SNM-1010L User Manual

Page 230

background image

SNM-1010L Data/Control Modem

Revision 0

Remote Control Channel Commands/Responses

MN/SNM1010L.OM



98



99


100


101


102


103



104


105



106


107


108


109


110


111

(ref. ‘CTSD_’command).


Carrier Only Mode
(ref. ‘COM_’command).


TX REED-Solomon Interleave Value
(ref. TRSI_’command)

TX 8PSK 2/3 IESS-310 Operation
(ref. ‘T310_’command).

RX 8PSK 2/3 IESS-310 Operation
(ref. ‘R310_’command).

LNB Power
(ref. ‘LNB_’command).

LNB Voltage
(ref. ‘LNBV_’command).


LNB Reference
(ref. ‘LNBR_’command)

LNB Current Monitor Low Threshold
(ref. ‘LNBL_’command)


LNB Current Monitor High Threshold
(ref. ‘LNBH_’command)


ODU Power
(ref. ‘ODU_’command).

FSK Link
(ref. ‘FSKL_’command).

ODU Reference
(ref. ‘ODUR_’command).

ODU Current Monitor Low Threshold
(ref. ‘ODUL_’command).


ODU Current Monitor High
Threshold
(ref. ‘ODUH_’command).




p98 = n, where ‘n’ is ‘0’ (OFF), ‘1’ (CENTER-CW),
‘2’ (DUAL-CW), or ‘3’ (OFFSET-CW).


p99 = nn, where ‘nn’ is the Interleave value.


p100 = n, where ‘n’ is ‘0’ (OFF) or ‘1’ (ON).


p101 = n, where ‘n’ is ‘0’ (OFF) or ‘1’ (ON).


p102 = n, where ‘n’ is ‘0’ (OFF) or ‘1’ (ON).


p103 = n, where ‘n’ is ‘0’ (13 Volts), ‘1’ (18 Volts), or ‘2’
(24 Volts).


p104 = n, where ‘n’ is ‘0’ (OFF) or ‘1’ (ON).


p105 = nnn, where ‘nnn’ is within 0 to 500 mA.



p106 = nnn, where ‘nnn’ is within 0 to 500 mA.



p107 = n, where ‘n’ is ‘0’ (OFF) or ‘1’ (ON).


p108 = n, where ‘n’ is ‘0’ (OFF) or ‘1’ (ON).


p109 = nnnn, where ‘nnnn’ is within 0 to 4000 mA.


p110 = nnnn, where ‘nnnn’ is within 0 to 4000 mA.



p111 = nnnn, where ‘nnnn’ is within 0 to 4000 mA.


Notes:

1. Parameters only valid in Transmit and Receive Continuous mode.

2. Parameters only valid in Transmit Continuous mode.

3. For any parameter other than the last parameter that is not returned, a comma (',') will be returned.

A–32