Function select:monitor, Function select:monitor:raw ber, Function select:monitor:corrected ber – Comtech EF Data SNM-1010L User Manual
Page 73: Function select:monitor:eb/no
SNM-1010L Data/Control Modem
Revision 0
Front Panel Operation
MN/SNM1010L.OM
3.4.2 FUNCTION
SELECT:MONITOR
FUNCTION SELECT
MONITOR
3.4.2.1 FUNCTION SELECT:MONITOR:RAW BER
RAW BER
NO DATA
Displays the current BER or “No Data” (if carrier is not locked).
Range: < m.m E-e to > m.m E-e.
Note: Low limit is based on performance. High limit is based on data/code rate.
3.4.2.2 FUNCTION SELECT:MONITOR:CORRECTED BER
CORRECTED BER
NO DATA
Displays the current corrected BER or “No Data” (if carrier is not locked).
Range: 1.0 E-3 to 1.0 E-12.
Note: Low limit is based on performance. High limit is 1.0 E-12
3.4.2.3 FUNCTION
SELECT:MONITOR:EB/NO
EB/NO
16.0
Displays the current Eb/N0 or “No Data” (if carrier is not locked).
Range: 2.0 to 16.0 dB.
Note: Low limit is based on the data rate. High limit is 16.0 dB.
3–25