beautypg.com

Configuration:demodulator:if loop back, Configuration:demodulator:ber threshold, Configuration:demodulator:sweep center – Comtech EF Data SNM-1010L User Manual

Page 63

background image

SNM-1010L Data/Control Modem

Revision 0

Front Panel Operation

MN/SNM1010L.OM

3.4.1.2.6

CONFIGURATION:DEMODULATOR:IF LOOP BACK

IF LOOP BACK

OFF


Displays the IF loop back status, either On or Off.

Note: Not recommended to turn On after initial installation with the MIDAS System.

3.4.1.2.7 CONFIGURATION:DEMODULATOR:BER

THRESHOLD

BER THRESHOLD

NONE


Displays the BER threshold .

If the BER threshold set is exceeded, a receive fault will be indicated by the modem
status indicators. BER threshold may be set from 1.0 E-3 to 1.0 E-8, or may be disabled
by specifying NONE.

3.4.1.2.8 CONFIGURATION:DEMODULATOR:SWEEP

CENTER

SWEEP CENTER

+ 0 HZ


Displays the sweep center frequency for the directed sweep function. When in directed
sweep, the value from the sweep monitor screen (when the modem was last locked)
should be entered for the sweep center frequency. The sweep center frequency can be set
in the range from –500000 to +500000 Hz.

Upon entry, the current sweep center frequency is displayed with the flashing cursor on
the first character. Press [

← ] or [→] to move the flashing cursor, and [↑ ] or [↓ ] to

increase or decrease the digit at the flashing cursor. Press to execute the
change.




3–15

This manual is related to the following products: