Configuration:demodulator:if loop back, Configuration:demodulator:ber threshold, Configuration:demodulator:sweep center – Comtech EF Data SNM-1010L User Manual
Page 63

SNM-1010L Data/Control Modem
Revision 0
Front Panel Operation
MN/SNM1010L.OM
3.4.1.2.6
CONFIGURATION:DEMODULATOR:IF LOOP BACK
IF LOOP BACK
OFF
Displays the IF loop back status, either On or Off.
Note: Not recommended to turn On after initial installation with the MIDAS System.
3.4.1.2.7 CONFIGURATION:DEMODULATOR:BER
THRESHOLD
BER THRESHOLD
NONE
Displays the BER threshold .
If the BER threshold set is exceeded, a receive fault will be indicated by the modem
status indicators. BER threshold may be set from 1.0 E-3 to 1.0 E-8, or may be disabled
by specifying NONE.
3.4.1.2.8 CONFIGURATION:DEMODULATOR:SWEEP
CENTER
SWEEP CENTER
+ 0 HZ
Displays the sweep center frequency for the directed sweep function. When in directed
sweep, the value from the sweep monitor screen (when the modem was last locked)
should be entered for the sweep center frequency. The sweep center frequency can be set
in the range from –500000 to +500000 Hz.
Upon entry, the current sweep center frequency is displayed with the flashing cursor on
the first character. Press [
← ] or [→] to move the flashing cursor, and [↑ ] or [↓ ] to
increase or decrease the digit at the flashing cursor. Press
change.
3–15