4.3.13

Built-In Diagnostic Tests (EFD_DIAG)

Note: These tests shall be performed by qualified personnel only.

This command starts the DAC Diagnostic software:

EFD_DIAG'cr'

is 0 to select the SNM-1010L control channel.

Wait several seconds. The User Port will display:

Diagnostic Test, Press F1 for Help.

>

Enter an ANSI F1 function key character sequence to display the diagnostic main menu:

F1: Help Screen

F2: Transfer Control to Flash Loader

F3: Transfer Control to PDREM Ram

F4: Restore Area 1 Defaults

F5: Restore Area 2 Defaults

1: Run Ram test

2: Run NOVRAM cycle power test

3: Run Chip Select test

4: Run EFBUS1 to EFBUS2 loopback test

5: Run EFBUS2 to EFBUS1 loopback test

6: Run Service Terminal loopback test

7: Alarm Input Test


To leave the diagnostic tests and return to SNM-1010L operational code, enter an ANSI
F4 function key character sequence.

CAUTION

Selecting any menu selection other than “F4” may cause unpredictable
operation of the SNM-1010L.

4.3.13.1 Help

Screen

To display the menu selection for the Comtech EF Data diagnostics, select menu option
“F1” by entering an ANSI F1.