Built-in diagnostic tests (efd_diag), Help screen, 13 built-in diagnostic tests (efd_diag) – Comtech EF Data SNM-1010L User Manual
Page 143: 1 help screen
SNM-1010L Data/Control Modem
Revision 0
User Port Operation
MN/SNM1010L.OM
4.3.13
Built-In Diagnostic Tests (EFD_DIAG)
Note: These tests shall be performed by qualified personnel only.
This command starts the DAC Diagnostic software:
EFD_DIAG'cr'
is 0 to select the SNM-1010L control channel.
Wait several seconds. The User Port will display:
•
Diagnostic Test, Press F1 for Help.
•
>
Enter an ANSI F1 function key character sequence to display the diagnostic main menu:
•
F1: Help Screen
•
F2: Transfer Control to Flash Loader
•
F3: Transfer Control to PDREM Ram
•
F4: Restore Area 1 Defaults
•
F5: Restore Area 2 Defaults
•
•
1: Run Ram test
•
2: Run NOVRAM cycle power test
•
3: Run Chip Select test
•
4: Run EFBUS1 to EFBUS2 loopback test
•
5: Run EFBUS2 to EFBUS1 loopback test
•
6: Run Service Terminal loopback test
•
7: Alarm Input Test
To leave the diagnostic tests and return to SNM-1010L operational code, enter an ANSI
F4 function key character sequence.
CAUTION
Selecting any menu selection other than “F4” may cause unpredictable
operation of the SNM-1010L.
4.3.13.1 Help
Screen
To display the menu selection for the Comtech EF Data diagnostics, select menu option
“F1” by entering an ANSI F1.
4–9