SNM-1010L Data/Control Modem

Revision 0

Remote Control Channel Commands/Responses

MN/SNM1010L.OM

Common Equipment
Status

Status:
Response:



MC CES_'cr'
CES_'cr'
M&C_xxx'cr'
INT_xxx'cr'
BAT_xxx'cr'
+5_xxx'cr'
+12_xxx'cr'
-12_xxx'cr'
MODE_xxxxxx'cr'
SFLT_xx'cr''lf']



M&C Module (OK/FLT)
Data Interface Module (OK/FLT)
Battery/Clock (OK/FLT)
+5V Power Supply (OK/FLT)
+12V Power Supply (OK/FLT)
-12V Power Supply (OK/FLT)
Mode (LOCAL or REMOTE)
Number of Stored Faults
Logged (0 through 10)

The common equipment status command causes the
return of a block of data indicating the common
equipment status.

A.6

ODU Configuration Status

Outdoor Unit Status

Status:
Response:

MC OUS_'cr'
OUS_'cr'
CURRENT_xxx'cr'
VOLTAGE_xxx'cr'
TEMP_xxx’cr’
PLL_xxx’cr’
CKSUM_xxx’cr’
SFLT_xx'cr''lf']



Current (FLT/OK)
Voltage (FLT/OK)
Temperature (FLT/OK)
Phase Lock Loop (FLT/OK)
Checksum (FLT/OK)
Number of stored faults logged (0 to 10)

Outdoor Unit
Temperature

Status:
Response:

MC ODUT_'cr'
ODUT_'cr'
ODU_sxx_yyy'cr’’lf']

Where s = + or – sign, xx = 0 to 99 degree in C and
yyy = OK or OOR (Out of Range).

Outdoor Unit Phase
Lock Loop

Status:
Response:

MC OPLL_'cr'
OPLL_xxxxxxxx'cr’’lf']

Where xxxxxxxx = UNLOCKED or OK.

Outdoor Unit Software
Version

Status:
Response:

MC OSV_'cr'
OSV_xxcr’’lf']

Where xx = 0 to 15.

Outdoor Unit Power
Class

Staus:
Response:

MC OPC_'cr'
OPC_xxcr’’lf']

Where xx = 2 to 60 Watts.


Outdoor Unit Address

Status:
Response:

MC OADR_'cr'
OADR_xxcr’’lf']

Where xx = 1 to 15.

Outdoor Unit TX
Output

Status:
Response:

MC ODUO_'cr'
ODUO_xxcr’’lf']

Where xxx = ON or OFF.

Outdoor Unit Power
Leveling

Status:
Response:

MC ODUP_'cr'
ODUP_xxcr’’lf']

Where xxx = ON or OFF.

A–20