3.4.3.2 FUNCTION SELECT:FAULTS AND ALARMS:DEMODULATOR

DEMODULATOR
+-++-----

CARRIER DETECT

Carrier detect fault. Indicates the decoder is not locked.

IF SYNTHESIZER

Demodulator IF synthesizer fault. Indicates the IF
synthesizer is not locked.

I CHANNEL

I channel activity fault. Indicates a loss of activity in the
I channel of the quadrature demodulator.

Q CHANNEL

Q channel activity fault. Indicates a loss of activity in
the Q channel of the quadrature demodulator.

BER THRESHOLD

Secondary alarm result of the BER threshold set in the
DEMOD Configuration menu.

MODULE

Demodulator/decoder module fault.

CONFIGURATION

Demodulator/decoder configuration fault.

LNB CURRENT

Low Noise Block Converter current fault.