3.4.3.2 FUNCTION SELECT:FAULTS AND ALARMS:DEMODULATOR
DEMODULATOR
+-++-----
CARRIER DETECT
Carrier detect fault. Indicates the decoder is not locked.
IF SYNTHESIZER
Demodulator IF synthesizer fault. Indicates the IF
synthesizer is not locked.
I CHANNEL
I channel activity fault. Indicates a loss of activity in the
I channel of the quadrature demodulator.
Q CHANNEL
Q channel activity fault. Indicates a loss of activity in
the Q channel of the quadrature demodulator.
BER THRESHOLD
Secondary alarm result of the BER threshold set in the
DEMOD Configuration menu.
MODULE
Demodulator/decoder module fault.
CONFIGURATION
Demodulator/decoder configuration fault.
LNB CURRENT
Low Noise Block Converter current fault.