Function select:faults and alarms:tx interface, 3 function select:faults and alarms:tx interface – Comtech EF Data SNM-1010L User Manual
Page 79
SNM-1010L Data/Control Modem
Revision 0
Front Panel Operation
MN/SNM1010L.OM
3.4.3.3 FUNCTION SELECT:FAULTS AND ALARMS:TX INTERFACE
TX INTERFACE
---------
TX DROP
Not Applicable.
TX DATA/AIS
Data or AIS. When data fault is selected in the Interface
Configuration menu, the fault indicates a data stable
condition. This indicates the data is all 1s or 0s (i.e., data is
not transitioning). When AIS is selected, the alarm
indicates the data is all 1s from customer data input to the
modem. When NONE is selected in the Interface
Configuration menu, the TX Data/AIS Fault/Alarm is not
activated.
Note: AIS is an alarm, not a switching fault.
TX CLK PLL
Transmitter phase-locked loop fault. Indicates the
transmitter Phase-Locked Loop (PLL) is not locked.
TX CLK ACTIVITY
Activity detector alarm of the selected interface transmit
clock. The interface will fall back to the internal clock when
this alarm is active.
TX AUDIO 1 CLIP
Not Applicable.
TX AUDIO 2 CLIP
Not Applicable.
CONFIGURATION
TX interface configuration fault.
Indicates the TX interface cannot execute a programmed
configuration parameter.
3–31