beautypg.com

Comtech EF Data SNM-1010L User Manual

Page 233

background image

SNM-1010L Data/Control Modem

Revision 0

Remote Control Channel Commands/Responses

MN/SNM1010L.OM

Bit 6 = 1 always.
Bit 5 = Battery/Clock.
Bit 4 = +5V power supply.
Bit 3 = +12V power supply.
Bit 2 = -12V power supply.
Bit 1 = reserved.
Bit 0 = reserved.


Character m: Interface Reed-Solomon unavailable seconds.

Bit 6 = 1 always.
Bit 5 = not used.
Bit 4 = not used.
Bit 3 through Bit 0 = reserved.

Character n: Common equipment fault status character 1.

Bit 6 = 1 always.
Bit 5 = not used.
Bit 4 = not used.
Bit 3 through Bit 0 = reserved.

Character o: Common equipment fault status character 2.

Bit 6 = 1 always.
Bit 5 = not used.
Bit 4 = not used.
Bit 3 through Bit 0 = reserved.

Character p: Interface Reed-Solomon Unavailable Seconds

Bit 6 = 1 always.
Bit 5 = not used.
Bit 4 = not used.

Bit 3 through Bit 0 = Binary representation (0 to 10) of

the number of Reed-Solomon unavailable seconds

Character q: Outdoor Unit Status Character 1.

Bit 6 = 1 always.
Bit 5 = not used.
Bit 4 = not used.

Bit 3 through Bit 0 = Binary representation (0 to 10) of
the number of Outdoor Unit stored faults.

Character r: Outdoor Unit Status Character 2.

Bit 6 = 1 always.
Bit 5 = reserved.
Bit 4 = reserved.
Bit 3 = reserved.
Bit 2 = reserved.
Bit 1 = reserved.
Bit 0 = reserved.

A–35