Comtech EF Data SNM-1010L User Manual
Page 233
SNM-1010L Data/Control Modem
Revision 0
Remote Control Channel Commands/Responses
MN/SNM1010L.OM
Bit 6 = 1 always.
Bit 5 = Battery/Clock.
Bit 4 = +5V power supply.
Bit 3 = +12V power supply.
Bit 2 = -12V power supply.
Bit 1 = reserved.
Bit 0 = reserved.
Character m: Interface Reed-Solomon unavailable seconds.
Bit 6 = 1 always.
Bit 5 = not used.
Bit 4 = not used.
Bit 3 through Bit 0 = reserved.
Character n: Common equipment fault status character 1.
Bit 6 = 1 always.
Bit 5 = not used.
Bit 4 = not used.
Bit 3 through Bit 0 = reserved.
Character o: Common equipment fault status character 2.
Bit 6 = 1 always.
Bit 5 = not used.
Bit 4 = not used.
Bit 3 through Bit 0 = reserved.
Character p: Interface Reed-Solomon Unavailable Seconds
Bit 6 = 1 always.
Bit 5 = not used.
Bit 4 = not used.
Bit 3 through Bit 0 = Binary representation (0 to 10) of
the number of Reed-Solomon unavailable seconds
Character q: Outdoor Unit Status Character 1.
Bit 6 = 1 always.
Bit 5 = not used.
Bit 4 = not used.
Bit 3 through Bit 0 = Binary representation (0 to 10) of
the number of Outdoor Unit stored faults.
Character r: Outdoor Unit Status Character 2.
Bit 6 = 1 always.
Bit 5 = reserved.
Bit 4 = reserved.
Bit 3 = reserved.
Bit 2 = reserved.
Bit 1 = reserved.
Bit 0 = reserved.
A–35