SNM-1010L Data/Control Modem

Revision 0

Remote Control Channel Commands/Responses

MN/SNM1010L.OM

System Modem Type

Command:
Response:

Status:
Response:

MC SMT_xxxxxxx'cr'
SMT_xxxxxxx'cr''lf']

MC SMT_'cr'
SMT_xxxxxxx'cr''lf']

Where: xxxxxx = IDR, IBS, DI, ASYNC, AUPC, EFD, or
CUSTOM.

Save Modem Config.

Command:
Response:

MC SMC_n'cr'
SMC_n'cr''lf']

Where: n = 1, 2, 3, 4, or 5 (stored configuration number).
This command saves the current modem configuration for
recall at a later time using the 'RMC_' command. Up to five
different modem configurations can be saved.

Recall Modem Config.

Command:
Response:

MC RMC_n'cr'
RMC_n'cr''lf']

Where: n = 1, 2, 3, 4, or 5 (stored configuration number).
This command causes the modem to be reprogrammed with
configuration parameters previously saved using the 'SMC_'
command. One of five saved configurations can be specified.

A.3.5 Automatic Uplink Power Control (AUPC)

AUPC Local Enable

Command:
Response:

Status:
Response:

MC LPC_xxx'cr'
LPC_xxx'cr''lf']

MC LPC_'cr'
LPC_xxx'cr''lf']

Where: xxx = ON or OFF.

Notes:

1. When programmed ON, the MOP (Modulator Output

Power) command is not allowed, only MOP status is
allowed.

2. ASYNC or AUPC Overhead only.

AUPC Nominal Power
Level

Command:
Response:

Status:
Response:

MC NOMP_snn.n'cr'
NOMP_snn.n'cr''lf']

MC NOMP_'cr'
NOMP_snn.n'cr''lf']

Where: snn.n = -40.0 to 0.0, in 0.1 steps (nominal range in
dBm).

Notes:

1. The nominal power range is modified relative to the

value specified by the modulator power offset
(MPO_).

2. ASYNC or AUPC Overhead only.

AUPC Maximum Power
Limit

Command:
Response:

Status:
Response:

MC MAXP_snn.n'cr'
MAXP_snn.n'cr''lf']

MC MAXP_'cr'
MAXP_snn.n'cr''lf']

Where: snn.n = -40.0 to 0.0, in 0.1 steps (nominal range in
dBm).

Notes:

1.

The nominal power range is modified relative to the
value specified by the modulator power offset
(MPO_).

2.

ASYNC or AUPC Overhead only.

AUPC Minimum Power
Limit

Command:
Response:

Status:
Response:

MC MINP_snn.n'cr'
MINP_snn.n'cr''lf']

MC MINP_'cr'
MINP_snn.n'cr''lf']

Where: snn.n = -40.0 to 0.0, in 0.1 steps (nominal range in
dBm).

Notes:

1. The nominal power range is modified relative to the

value specified by the modulator power offset
(MPO_).

2. ASYNC or AUPC Overhead only.

AUPC Eb/N0 Target Set
Point

Command:
Response:

Status:
Response:

MC ENSP_nn.n'cr'
ENSP_nn.n'cr''lf']

MC ENSP_'cr'
ENSP_nn.n'cr''lf']

Where: nn.n = 3.2 to 16.0, in 0.1 increments (Eb/N0 in dB).

Note: ASYNC or AUPC Overhead only.

AUPC Maximum
Tracking Rate

Command:
Response:

Status:
Response:

MC MAXT_n.n'cr'
MAXT_n.n'cr''lf']

MC MAXT_'cr'
MAXT_n.n'cr''lf']

Where: n.n = 0.5 to 6.0, in 0.5 increments (max tracking rate
in dBm/minute).

Note: ASYNC or AUPC Overhead only.

AUPC Local Carrier
Loss Action

Command:
Response:

Status:
Response:

MC LCL_xxxx'cr'
LCL_xxxx'cr''lf']

MC LCL_'cr'
LCL_xxxx'cr''lf']

Where: xxxx = HOLD, NOM, or MAX (power level setting
when local carrier loss).

Note: ASYNC or AUPC Overhead only.

A–12