SNM-1010L Data/Control Modem

Revision 0

Remote Control Channel Commands/Responses

MN/SNM1010L.OM

Modulator Rate
Status

Status:
Response:

MC MR_'cr'
MR_nnnn_mmmm.mmm'cr''lf']

Where:.


nnnn = 1/2 (QPSK 1/2), [coder rate], 3/4 (QPSK 3/4),
7/8 (QPSK 7/8), BP12 (BPSK 1/2), 8P23 (8PSK 2/3),
OQ12 (OQPSK 1/2), OQ34 (OQPSK 3/4), OQ78
(OQPSK 7/8), OQPSK (OQPSK 1/1), BPSK (BPSK
1/1), QPSK (QPSK 1/1) 2144 (BPSK 21/44), B516
)BPSK 5/16),
8P34 (8PSK 3/4)

mmmm.mmm = Data rate in kHz

Demodulator Rate
Status

Status:
Response:

MC DR_'cr'
DR_nnnn_mmmm.mmm'cr''lf']

Where:

nnnn = 1/2 (QPSK 1/2), [coder rate], 3/4 (QPSK 3/4),
7/8 (QPSK 7/8), BP12 (BPSK 1/2), 8P23 (8PSK 2/3),
(OQ12 (OQPSK 1/2), OQ34 (OQPSK 3/4), OQ78
(OQPSK 7/8), OQPSK (OQPSK 1/1), BPSK (BPSK
1/1), QPSK (QPSK 1/1) 2144 (BPSK 21/44), B516
)BPSK 5/16),
8P34 (8PSK 3/4)


mmmm.mmm = Data rate in kHz.

Receive Signal Level
Status

Status:
Response:

MC RSL_'cr'
RSL_xsnn.ndBm'cr''lf']

Where:
x = < or > (data modifier to indicate that the receive signal
level is less than or greater than the returned value).
s = + or - (receive signal level sign, plus or minus).
nn.n = 0.0 to 99.9 (receive signal level magnitude).

Notes:

1. The 'x' (< or >) parameter is only returned if the level

has exceeded the computational resolution of the
system.

2. 'No Data' is returned if the level cannot be calculated.
3. Sampling' is returned if not enough data is currently

available to calculate the level.

Interface Buffer Fill
Status

Status:
Response:

MC IBFS_'cr'
IBFS_nn%'cr''lf']

Where: nn = 1 to 99 (relative to buffer depth).

LNB Current Monitor
Status

Status:
Response:

MC LNBC_'cr'
LNBC_nnn'cr''lf']

Where: nnn = 0 to 500 (in 1 mA steps)

Notes:
The 'x' (< or >) parameter is only returned if the level has
exceeded the computational resolution of the system.
'No Data' is returned if the level cannot be calculated.
Sampling' is returned if not enough data is currently
available to calculate the level.

ODU Current Monitor
Status


Status:
Response:

MC ODUC_'cr'
ODUC_nnnn'cr''lf']

Where: nnn = 0 to 4000 (in 1 mA steps)

Notes:

1. The 'x' (< or >) parameter is only returned if the level

has exceeded the computational resolution of the
system.

2. 'No Data' is returned if the level cannot be calculated.
3. Sampling' is returned if not enough data is currently

available to calculate the level.

A–23