beautypg.com

General specifications, 4 general specifications – Comtech EF Data SNM-1010L User Manual

Page 26

background image

SNM-1010L Data/Control Modem

Revision 0

Introduction

MN/SNM1010L.OM

1.4 General

Specifications

General Specifications
Digital Data Rate

2.4 kbps to 5.0 Mbps, in 1 bit/s step


Note: In some applications the practical lower data rate is typically 19.2
kbps or higher., depending upon the performance of equipment used in
conjunction with the modem. These applications include the use of a
BUC or a LNB.

Symbol Rate

4.8 k symbols/s to 2.5 Msym/s

Modulation/Demodulation

BPSK R = 1/2
QPSK R = 1/2, 3/4, and 7/8
OQPSK R = 1/2, 3/4, and 7/8
8PSK

R = 2/3

Plesiochronous/Doppler Buffer

1 to 99 ms, in 1 ms steps up to 2.6 Mbps
32 to 262,144 bits in 16 bit steps

Forward Error Correction (FEC)

Viterbi, K=7, R = 1/2, 3/4, and 7/8
Sequential, R = 1/2, 3/4, and 7/8
Reed-Solomon Concatenated per Closed Network, R = 225/205
Trellis, R = 2/3 (8PSK)
Turbo Product Coding, R = 3/4, 21/44, and 5/16
Uncoded

Data Scrambling

IESS-308 (V.35 Intelsat), IESS-309/310, FDC, V.35 (EFD/CSC),
Modified V.35, None

External Reference Input

EXT1, EXT5, EXT10, EXT20 MHz

Note: Only 10 MHz allowed when operating with BUC requiring 10
MHz reference from modem.

External Reference Output Level
(Sourcing)

10 MHz, 0 to 10 dBm

Diagnostic Features

Baseband Loopback
BER Monitoring
Buffer Fill Status Monitoring
Input IF Power Monitoring
Interface Loopback
IF Loopback
Fault Monitoring (includes current and stored faults)
Remote Control via Serial Port
RF Loopback


1–6

This manual is related to the following products: