Comtech EF Data SNM-1010L User Manual
Page 203
SNM-1010L Data/Control Modem
Revision 0
Remote Control Channel Commands/Responses
MN/SNM1010L.OM
Transmit BPSK Data
Ordering for Continuous
Mode
Command:
Response:
Status:
Response:
MC TDA_xxx'cr' TDA_xxx'cr''lf']
MC TDA_'cr'
TDA_xxx'cr''lf']
Where: xxx = NRM (Standard) or INV (Non-
Standard).
Carrier Only Mode
Command:
Response:
Status:
Response:
MC COM_xxxxxx'cr'
COM_xxxxxx'cr''lf']
MC COM_xxxxxx'cr'
COM_xxxxxx'cr''lf']
Where: xxxxxx = OFF (NORMAL-MODULATED),
DUAL (DUAL-CW), OFFSET (OFFSET-CW),
CENTER (CENTER-CW).
Modulator Preamble for
Burst Mode
Command:
Response:
Status: Response:
MC MPRE_n'cr' MPRE_n'cr''lf']
MC MPRE_'cr'
MPRE_n'cr''lf']
Where: n = 1 (Preamble 1) or 2 (Preamble 2).
Reed-Solomon Interleave
Value
Command:
Response:
Status:
Response:
MC TRSI_xx'cr'
TRSI_xx'cr''lf']
MC TRSI_'cr'
TRSI_xx'cr''lf']
Where: xx = 4, 8, or 16.
TX 8PSK 2/3 IESS-310
Operation
Command:
Response:
Status:
Response:
MC T310_xxx'cr'
T310_xxx'cr''lf']
MC T310_'cr'
T310_xxx'cr''lf']
Where: xxx = ON or OFF.
TX FSK Output
Command:
Response:
Status:
Response:
Where: xxx = On or OFF.
ODU Power
Command:
Response:
Status:
Response:
Where: xxx = On or OFF.
ODU Reference Enable
Command:
Response:
Status:
Response:
Where: xxx = On or OFF.
ODU Power Monitor
Low Current Threshold
Command:
Response:
Status:
Response:
Where: xxx = 0 to 4000 mA in 100 mA steps
ODU Power Monitor
High Current Threshold
Command:
Response:
Status:
Response:
Where: xxx = 0 to 4000 mA in 100 mA steps.
A–5