Utility:system:remote address, Utility:system:remote type, Utility:system:operation mode – Comtech EF Data SNM-1010L User Manual
Page 102
SNM-1010L Data/Control Modem
Revision 0
Front Panel Operation
MN/SNM1010L.OM
REMOTE BAUD RATE
19.200 BPS NONE
The parity and baud rate settings of the modem are displayed.
To change the modem parity, press [ENTER].
• Press [←] or [→] to position the cursor over the parameter to be changed.
• Press [↑] or [↓] to change the parameter.
• Once the parameters are displayed as desired, press [ENTER] to set the baud rate
and parity.
• The parity can be set to EVEN, ODD, or NONE.
The baud rate is 19200 bit/s.
3.4.5.8.3 UTILITY:SYSTEM:REMOTE
ADDRESS
REMOTE ADDRESS
1
The current modem address is displayed (1 to 255).
Note: 0 is reserved as a global address.
To change the remote address, press [ENTER]. Press [
↑] or [↓] to make the selection. Press
[ENTER] to execute the change.
3.4.5.8.4 UTILITY:SYSTEM:REMOTE
TYPE
REMOTE TYPE
RS485 (2-WIRE)
Select EIA-485 (2-Wire), EIA-485 (4-Wire), or EIA-232.
3.4.5.8.5 UTILITY:SYSTEM:OPERATION
MODE