Error reporting, Error reporting -10 – Altera Arria 10 Avalon-ST User Manual
Page 53

Parameter
Possible Values
Default Value
Description
functions this field is reserved and must be hardwired to
0x0000b. Four time value ranges are defined:
• Range A: 50 us to 10 ms
• Range B: 10 ms to 250 ms
• Range C: 250 ms to 4 s
• Range D: 4 s to 64 s
Bits are set to show timeout value ranges supported. The
function must implement a timeout value in the range
50 s to 50 ms. The following values specify the range:
• None—Completion timeout programming is not
supported
• 0001 Range A
• 0010 Range B
• 0011 Ranges A and B
• 0110 Ranges B and C
• 0111 Ranges A, B, and C
• 1110 Ranges B, C and D
• 1111 Ranges A, B, C, and D
All other values are reserved. Altera recommends that
the completion timeout mechanism expire in no less
than 10 ms.
Disable
completion
timeout
On/Off
On
Disables the completion timeout mechanism. When On,
the core supports the completion timeout disable
mechanism via the PCI Express
Device Control
Register 2
. The Application Layer logic must
implement the actual completion timeout mechanism
for the required ranges.
Error Reporting
Table 4-7: Error Reporting
Parameter
Value
Default Value
Description
Advanced
error
reporting
(AER)
On/Off
Off
When On, enables the Advanced Error Reporting (AER)
capability.
4-10
Error Reporting
UG-01145_avst
2014.08.18
Altera Corporation
Parameter Settings