Throughput optimization, Throughput optimization -1 – Altera Arria 10 Avalon-ST User Manual
Page 190
Throughput Optimization
13
2015.05.04
UG-01145_avst
The PCI Express Base Specification defines a flow control mechanism to ensure efficient transfer of TLPs.
Each transmitter, the write requester in this case, maintains a
credit limit
register and a
credits
consumed
register. The
credit limit
register is the sum of all credits received by the receiver, the write
completer in this case. The
credit limit
register is initialized during the flow control initialization phase
of link initialization and then updated during operation by Flow Control (FC) Update DLLPs. The
credits consumed
register is the sum of all credits consumed by packets transmitted. Separate
credit
limit
and
credits consumed
registers exist for each of the six types of Flow Control:
• Posted Headers
• Posted Data
• Non-Posted Headers
• Non-Posted Data
• Completion Headers
• Completion Data
Each receiver also maintains a
credit allocated
counter which is initialized to the total available space
in the RX buffer (for the specific Flow Control class) and then incremented as packets are pulled out of
the RX buffer by the Application Layer. The value of this register is sent as the FC Update DLLP value.
©
2015 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are
trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as
trademarks or service marks are the property of their respective holders as described at
www.altera.com/common/legal.html
. Altera warrants performance
of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any
products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information,
product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device
specifications before relying on any published information and before placing orders for products or services.
www.altera.com
101 Innovation Drive, San Jose, CA 95134