CLI Commands: Switching
304
5.5 Redundant Coupling
PSSnet SHL - Command Line Interface
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
5.5.4 ring-coupling net-coupling
Coupling mode refers to the type of coupled network.
Possible values are:
D
network ,if you wish to couple a line-type configuration.
D
ring-only ,if you wish to couple a HIPER-Ring.
Default
none
Format
ring-coupling net-coupling <{network|ring-only}>
Mode
Global Config
5.5.5 ring-coupling operation
Configure the Ring Coupling's operation setting. Possible values are:
D
on Enable the current Ring Coupling configuration.
D
off Disable the current Ring Coupling configuration.
Default
off
Format
ring-coupling operation <{off|on}>
Mode
Global Config