beautypg.com

4 inlinepower, 5 clear inlinepower, 4inlinepower 251 5.11.5clear inlinepower – Pilz PSSnet SHL 8T MRP User Manual

Page 251

background image

PSSnet SHL - Command Line Interface

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany

4.11 PoE - Power over Ethernet

251

4.11.4 inlinepower

Configure the portrelated Inline Power parameters.
Note: The interface name you enter in the name-command.
Format

inlinepower {admin-mode {disable|enable} |
priority {critical|high|low} }

Mode

Interface Config

admin-mode

Configure the port-related Inline Power administrative setting (enable
or disable, default: enable).

priority

Configure the Inline Power priority for this port. In case of power scar-
city, inline power on ports configured with the lowest priority is
dropped first. Possible values are: critical, high or low, default: low.
The highest priority is critical.

4.11.5 clear inlinepower

Reset the Inline Power parameters to default settings.
Format

clear inlinepower

Mode

Privileged EXEC

This manual is related to the following products: