4 inlinepower, 5 clear inlinepower, 4inlinepower 251 5.11.5clear inlinepower – Pilz PSSnet SHL 8T MRP User Manual
Page 251

PSSnet SHL - Command Line Interface
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
4.11 PoE - Power over Ethernet
251
4.11.4 inlinepower
Configure the portrelated Inline Power parameters.
Note: The interface name you enter in the name-command.
Format
inlinepower {admin-mode {disable|enable} |
priority {critical|high|low} }
Mode
Interface Config
admin-mode
Configure the port-related Inline Power administrative setting (enable
or disable, default: enable).
priority
Configure the Inline Power priority for this port. In case of power scar-
city, inline power on ports configured with the lowest priority is
dropped first. Possible values are: critical, high or low, default: low.
The highest priority is critical.
4.11.5 clear inlinepower
Reset the Inline Power parameters to default settings.
Format
clear inlinepower
Mode
Privileged EXEC